MANUAL
SD-8202GT-PEQ
SD-8103GT-PEQ
Wireless Request-to-Exit Plates
SD-8202GT-PEQ
SD-8103GT-PEQ
NOTE: Products with a model number that ends with “Q” or have a round green “Q” sticker represent RoHs compliant products.
ENFORCER Wireless Request-to-Exit Plates
Installation:
1. Find a suitable location for the wireless request-to-exit plate.
NOTE: Do not house the plate in a metal box, this will greatly reduce the range.
2. The wireless request-to-exit plate can be either surface mounted or flush mounted.
3. Test the operation of the wireless request-to-exit plate in the location where it will be installed.
NOTE: The wireless request-to-exit plate first needs to programmed into the SK-910R
receiver before testing. See SK-910R receiver manual for transmitter learning procedure.
4. Check and make sure the battery clip is securely connected. Then mount the wireless request-
to-exit plate in the back-box and secure it with the 2 included screws.
Changing the Battery:
The wireless request-to-exit plate has multi-colored LED that illuminates blue when the button is
pressed. When the battery begins to run low, the LED will illuminate red. To change the battery:
1. Remove the 2 screws from the front of the plate and remove the plate from the back-box.
2. Remove the battery clip from the 9V battery and remove the battery from the bracket.
3. Place the new battery in the bracket and snap the battery clip to the new battery.
4. Test the unit with the new battery. The LED should illuminate blue.
5. Put the plate back in the housing and secure it to the back-box using the screws on the front.
Sample Application: Connecting to multiple wireless devices to an
Electromagnetic Lock:
SK-919TDWS-BU
Wired 1-channel
Transmitter
SK-910R
Wireless Receiver
E-964-Q660Q
Red=Low Battery
Quad Photobeam
Detectors
SD-8202GT-PEQ
Wireless
Request-to-Exit Plate
1
3
2
4
ENFORCER
SK-919TP4D-P
Wireless 4-Button
Desktop Transmitter
SK-919TP4H-N
Hand-held 4-Button
Transmitter
E-941SA-1200
Electromagnetic Lock
SECO-LARM U.S.A., Inc
3
ENFORCER Wireless Request-to-Exit Plates
Troubleshooting:
LED is red
LED does not light
9V battery is low, replace with new one
Check battery connection
Replace 9V battery
LED lights blue, but does not
activate lock
Check to make sure wireless request-to-exit plate is not
housed in a metal box
Test wireless request-to-exit plate closer to the receiver
Clear codes from receiver, and re-learn wireless plate
transmitter code
Also Available from SECO-LARM:
Handheld
Transmitters
Wireless RF
Receivers
Desktop RF
Transmitters
Wired 1-channel
Transmitter
SK-919TP4H-NU
SK-919TDWS-BU
SK-910R4
SK-919TP4D-P
(shown)
(shown)
(shown)
Slim-Line
Push-to-Exit Plates
Pendant-Style
Transmitters
Single-Gang
Push-to-Exit Plates
Extended Range
Antenna
SD-7104SGEX1Q
SD-7201GC-PE1
SK-91ERSD
SK-919TP4J-N
(shown)
(shown)
(shown)
WARRANTY This SECO-LARM product is warranted against defects in material and workmanship while used in normal
service for a period of one (1) year from the date of sale to the original consumer customer. SECO-LARM’s obligation is
limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM.
This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect,
repair, or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines
that such equipment is not operating properly as a result of causes other than defects in material and workmanship.
The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to replacement or repair only,
at SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential
personal or property damages of any kind to the purchaser or anyone else.
NOTICE: The information and specifications printed in this manual are current at the time of publication. However, the
SECO-LARM policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right
to change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors.
Copyright © 2008 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in
whole or in part, without the written permission of SECO-LARM.
SECO-LARM® U.S.A., Inc.
PITSW1
16842 Millikan Avenue, Irvine, CA 92606
E-mail: sales@seco-larm.com
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326
mi-SD-8XXX.docx
4
SECO-LARM U.S.A., Inc.
|
RCA Flat Panel Television M50WH186 User Guide
Renesas Network Card HS7047ECH61H User Guide
RF Link Technology Security Camera AWS 5832 VSR User Guide
Rosewill Projector Accessories RHMS 11002 User Guide
Royal Sovereign Paper Shredder RDS 901X User Guide
Ryobi Trimmer RY15524 User Guide
Samsung Cell Phone VI A820 User Guide
Samsung Printer 4050N User Guide
Samsung Printer ML 3561N User Guide
Sansui Flat Panel Television HDLCD1900A User Guide